diff options
author | Brendan Jackman <brendan.jackman@arm.com> | 2016-08-17 16:14:59 +0100 |
---|---|---|
committer | Zhang Rui <rui.zhang@intel.com> | 2016-08-19 21:32:18 +0800 |
commit | a305a4387acb01cecadeeea5151c049a022a1bfc (patch) | |
tree | 4563fb3c6b8956491b1326ba5ec3d160b9850fda /Documentation | |
parent | 694d0d0bb2030d2e36df73e2d23d5770511dbc8d (diff) |
thermal: cpu_cooling: Fix NULL dereference in cpufreq_state2power
Currently all CPU cooling devices share a
`struct thermal_cooling_device_ops` instance. The thermal core uses the
presence of functions in this struct to determine if a cooling device
has a power model (see cdev_is_power_actor). cpu_cooling.c adds the
power model functions to the shared struct when a device is registered
with a power model.
Therefore, if a CPU cooling device is registered using
[of_]cpufreq_power_cooling_register, _all_ devices will be determined to
have a power model, including any registered with
[of_]cpufreq_cooling_register. This can result in cpufreq_state2power
being called on a device where dyn_power_table is NULL.
With this commit, instead of having a shared thermal_cooling_device_ops
which is mutated, we have two versions: one with the power functions and
one without.
Signed-off-by: Brendan Jackman <brendan.jackman@arm.com>
Cc: Amit Daniel Kachhap <amit.kachhap@gmail.com>
Cc: Viresh Kumar <viresh.kumar@linaro.org>
Cc: Javi Merino <javi.merino@arm.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'Documentation')
0 files changed, 0 insertions, 0 deletions