1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
|
[
{,
"EventCode": "0x100f2",
"EventName": "PM_1PLUS_PPC_CMPL",
"BriefDescription": "1 or more ppc insts finished",
"PublicDescription": "1 or more ppc insts finished (completed)"
},
{,
"EventCode": "0x400f2",
"EventName": "PM_1PLUS_PPC_DISP",
"BriefDescription": "Cycles at least one Instr Dispatched",
"PublicDescription": "Cycles at least one Instr Dispatched. Could be a group with only microcode. Issue HW016521"
},
{,
"EventCode": "0x100fa",
"EventName": "PM_ANY_THRD_RUN_CYC",
"BriefDescription": "One of threads in run_cycles",
"PublicDescription": "Any thread in run_cycles (was one thread in run_cycles)"
},
{,
"EventCode": "0x4000a",
"EventName": "PM_CMPLU_STALL",
"BriefDescription": "Completion stall",
"PublicDescription": ""
},
{,
"EventCode": "0x4d018",
"EventName": "PM_CMPLU_STALL_BRU",
"BriefDescription": "Completion stall due to a Branch Unit",
"PublicDescription": ""
},
{,
"EventCode": "0x2c012",
"EventName": "PM_CMPLU_STALL_DCACHE_MISS",
"BriefDescription": "Completion stall by Dcache miss",
"PublicDescription": ""
},
{,
"EventCode": "0x2c018",
"EventName": "PM_CMPLU_STALL_DMISS_L21_L31",
"BriefDescription": "Completion stall by Dcache miss which resolved on chip ( excluding local L2/L3)",
"PublicDescription": ""
},
{,
"EventCode": "0x2c016",
"EventName": "PM_CMPLU_STALL_DMISS_L2L3",
"BriefDescription": "Completion stall by Dcache miss which resolved in L2/L3",
"PublicDescription": ""
},
{,
"EventCode": "0x4c016",
"EventName": "PM_CMPLU_STALL_DMISS_L2L3_CONFLICT",
"BriefDescription": "Completion stall due to cache miss that resolves in the L2 or L3 with a conflict",
"PublicDescription": "Completion stall due to cache miss resolving in core's L2/L3 with a conflict"
},
{,
"EventCode": "0x4c01a",
"EventName": "PM_CMPLU_STALL_DMISS_L3MISS",
"BriefDescription": "Completion stall due to cache miss resolving missed the L3",
"PublicDescription": ""
},
{,
"EventCode": "0x4c018",
"EventName": "PM_CMPLU_STALL_DMISS_LMEM",
"BriefDescription": "Completion stall due to cache miss that resolves in local memory",
"PublicDescription": "Completion stall due to cache miss resolving in core's Local Memory"
},
{,
"EventCode": "0x2c01c",
"EventName": "PM_CMPLU_STALL_DMISS_REMOTE",
"BriefDescription": "Completion stall by Dcache miss which resolved from remote chip (cache or memory)",
"PublicDescription": "Completion stall by Dcache miss which resolved on chip ( excluding local L2/L3)"
},
{,
"EventCode": "0x4c012",
"EventName": "PM_CMPLU_STALL_ERAT_MISS",
"BriefDescription": "Completion stall due to LSU reject ERAT miss",
"PublicDescription": ""
},
{,
"EventCode": "0x4d016",
"EventName": "PM_CMPLU_STALL_FXLONG",
"BriefDescription": "Completion stall due to a long latency fixed point instruction",
"PublicDescription": ""
},
{,
"EventCode": "0x2d016",
"EventName": "PM_CMPLU_STALL_FXU",
"BriefDescription": "Completion stall due to FXU",
"PublicDescription": ""
},
{,
"EventCode": "0x30036",
"EventName": "PM_CMPLU_STALL_HWSYNC",
"BriefDescription": "completion stall due to hwsync",
"PublicDescription": ""
},
{,
"EventCode": "0x4d014",
"EventName": "PM_CMPLU_STALL_LOAD_FINISH",
"BriefDescription": "Completion stall due to a Load finish",
"PublicDescription": ""
},
{,
"EventCode": "0x2c010",
"EventName": "PM_CMPLU_STALL_LSU",
"BriefDescription": "Completion stall by LSU instruction",
"PublicDescription": ""
},
{,
"EventCode": "0x10036",
"EventName": "PM_CMPLU_STALL_LWSYNC",
"BriefDescription": "completion stall due to isync/lwsync",
"PublicDescription": ""
},
{,
"EventCode": "0x30006",
"EventName": "PM_CMPLU_STALL_OTHER_CMPL",
"BriefDescription": "Instructions core completed while this tread was stalled",
"PublicDescription": "Instructions core completed while this thread was stalled"
},
{,
"EventCode": "0x4c01c",
"EventName": "PM_CMPLU_STALL_ST_FWD",
"BriefDescription": "Completion stall due to store forward",
"PublicDescription": ""
},
{,
"EventCode": "0x1001c",
"EventName": "PM_CMPLU_STALL_THRD",
"BriefDescription": "Completion Stalled due to thread conflict. Group ready to complete but it was another thread's turn",
"PublicDescription": "Completion stall due to thread conflict"
},
{,
"EventCode": "0x1e",
"EventName": "PM_CYC",
"BriefDescription": "Cycles",
"PublicDescription": ""
},
{,
"EventCode": "0x10006",
"EventName": "PM_DISP_HELD",
"BriefDescription": "Dispatch Held",
"PublicDescription": ""
},
{,
"EventCode": "0x4003c",
"EventName": "PM_DISP_HELD_SYNC_HOLD",
"BriefDescription": "Dispatch held due to SYNC hold",
"PublicDescription": ""
},
{,
"EventCode": "0x200f8",
"EventName": "PM_EXT_INT",
"BriefDescription": "external interrupt",
"PublicDescription": ""
},
{,
"EventCode": "0x400f8",
"EventName": "PM_FLUSH",
"BriefDescription": "Flush (any type)",
"PublicDescription": ""
},
{,
"EventCode": "0x30012",
"EventName": "PM_FLUSH_COMPLETION",
"BriefDescription": "Completion Flush",
"PublicDescription": ""
},
{,
"EventCode": "0x3000c",
"EventName": "PM_FREQ_DOWN",
"BriefDescription": "Power Management: Below Threshold B",
"PublicDescription": "Frequency is being slewed down due to Power Management"
},
{,
"EventCode": "0x4000c",
"EventName": "PM_FREQ_UP",
"BriefDescription": "Power Management: Above Threshold A",
"PublicDescription": "Frequency is being slewed up due to Power Management"
},
{,
"EventCode": "0x2000a",
"EventName": "PM_HV_CYC",
"BriefDescription": "Cycles in which msr_hv is high. Note that this event does not take msr_pr into consideration",
"PublicDescription": "cycles in hypervisor mode"
},
{,
"EventCode": "0x3405e",
"EventName": "PM_IFETCH_THROTTLE",
"BriefDescription": "Cycles in which Instruction fetch throttle was active",
"PublicDescription": "Cycles instruction fecth was throttled in IFU"
},
{,
"EventCode": "0x10014",
"EventName": "PM_IOPS_CMPL",
"BriefDescription": "Internal Operations completed",
"PublicDescription": "IOPS Completed"
},
{,
"EventCode": "0x3c058",
"EventName": "PM_LARX_FIN",
"BriefDescription": "Larx finished",
"PublicDescription": ""
},
{,
"EventCode": "0x1002e",
"EventName": "PM_LD_CMPL",
"BriefDescription": "count of Loads completed",
"PublicDescription": ""
},
{,
"EventCode": "0x10062",
"EventName": "PM_LD_L3MISS_PEND_CYC",
"BriefDescription": "Cycles L3 miss was pending for this thread",
"PublicDescription": ""
},
{,
"EventCode": "0x30066",
"EventName": "PM_LSU_FIN",
"BriefDescription": "LSU Finished an instruction (up to 2 per cycle)",
"PublicDescription": ""
},
{,
"EventCode": "0x2003e",
"EventName": "PM_LSU_LMQ_SRQ_EMPTY_CYC",
"BriefDescription": "LSU empty (lmq and srq empty)",
"PublicDescription": ""
},
{,
"EventCode": "0x2e05c",
"EventName": "PM_LSU_REJECT_ERAT_MISS",
"BriefDescription": "LSU Reject due to ERAT (up to 4 per cycles)",
"PublicDescription": ""
},
{,
"EventCode": "0x4e05c",
"EventName": "PM_LSU_REJECT_LHS",
"BriefDescription": "LSU Reject due to LHS (up to 4 per cycle)",
"PublicDescription": ""
},
{,
"EventCode": "0x1e05c",
"EventName": "PM_LSU_REJECT_LMQ_FULL",
"BriefDescription": "LSU reject due to LMQ full ( 4 per cycle)",
"PublicDescription": ""
},
{,
"EventCode": "0x1001a",
"EventName": "PM_LSU_SRQ_FULL_CYC",
"BriefDescription": "Storage Queue is full and is blocking dispatch",
"PublicDescription": "SRQ is Full"
},
{,
"EventCode": "0x40014",
"EventName": "PM_PROBE_NOP_DISP",
"BriefDescription": "ProbeNops dispatched",
"PublicDescription": ""
},
{,
"EventCode": "0x600f4",
"EventName": "PM_RUN_CYC",
"BriefDescription": "Run_cycles",
"PublicDescription": ""
},
{,
"EventCode": "0x3006c",
"EventName": "PM_RUN_CYC_SMT2_MODE",
"BriefDescription": "Cycles run latch is set and core is in SMT2 mode",
"PublicDescription": ""
},
{,
"EventCode": "0x2006c",
"EventName": "PM_RUN_CYC_SMT4_MODE",
"BriefDescription": "cycles this threads run latch is set and the core is in SMT4 mode",
"PublicDescription": "Cycles run latch is set and core is in SMT4 mode"
},
{,
"EventCode": "0x1006c",
"EventName": "PM_RUN_CYC_ST_MODE",
"BriefDescription": "Cycles run latch is set and core is in ST mode",
"PublicDescription": ""
},
{,
"EventCode": "0x500fa",
"EventName": "PM_RUN_INST_CMPL",
"BriefDescription": "Run_Instructions",
"PublicDescription": ""
},
{,
"EventCode": "0x1e058",
"EventName": "PM_STCX_FAIL",
"BriefDescription": "stcx failed",
"PublicDescription": ""
},
{,
"EventCode": "0x20016",
"EventName": "PM_ST_CMPL",
"BriefDescription": "Store completion count",
"PublicDescription": ""
},
{,
"EventCode": "0x200f0",
"EventName": "PM_ST_FIN",
"BriefDescription": "Store Instructions Finished",
"PublicDescription": "Store Instructions Finished (store sent to nest)"
},
{,
"EventCode": "0x20018",
"EventName": "PM_ST_FWD",
"BriefDescription": "Store forwards that finished",
"PublicDescription": ""
},
{,
"EventCode": "0x10026",
"EventName": "PM_TABLEWALK_CYC",
"BriefDescription": "Cycles when a tablewalk (I or D) is active",
"PublicDescription": "Tablewalk Active"
},
{,
"EventCode": "0x300f8",
"EventName": "PM_TB_BIT_TRANS",
"BriefDescription": "timebase event",
"PublicDescription": ""
},
{,
"EventCode": "0x2000c",
"EventName": "PM_THRD_ALL_RUN_CYC",
"BriefDescription": "All Threads in Run_cycles (was both threads in run_cycles)",
"PublicDescription": ""
},
{,
"EventCode": "0x30058",
"EventName": "PM_TLBIE_FIN",
"BriefDescription": "tlbie finished",
"PublicDescription": ""
},
{,
"EventCode": "0x10060",
"EventName": "PM_TM_TRANS_RUN_CYC",
"BriefDescription": "run cycles in transactional state",
"PublicDescription": ""
},
{,
"EventCode": "0x2e012",
"EventName": "PM_TM_TX_PASS_RUN_CYC",
"BriefDescription": "cycles spent in successful transactions",
"PublicDescription": "run cycles spent in successful transactions"
},
]
|